TOP >  Installed Equipment and Facilities >  Cell Culture Chamber

Cell Culture Chamber



Safety Cabinet

Model
(Manufacturer)
MHE-131AJ (SANYO)
Features and Specifications, etc. [Overview]
 This device allows for aseptic operations such as cell culture and reagent preparation.

[Specifications]
 - Work area dimensions: Width 1,200 mm x Depth 601 mm x Height 680 mm (stainless steel plate)
 - Front shutter: Reinforced glass with aluminum frame (auto-balance mechanism, UV protection)
 - Lighting: Fluorescent lamp (FL-40SD), germicidal lamp (GL-15)
 - Piping: For gas burner, vacuum, and drain valve
 - Burner: Ignites only when the fan is operating
 - Intake filter: Standard HEPA filter
 - Exhaust filter: Low pressure drop HEPA filter
 - Cleanliness level: Class 100

[Features]
 - The work area is made of durable stainless steel.
- Wide clean work area with minimal airflow disturbance.
- Low noise and low vibration due to the small fan motor.
[Usage Examples]
 - Maintenance and subculturing of cultured cells.
- Filtration sterilization of media and reagents.

[Note]
 This device maintains a negative pressure inside the chamber to keep the samples clean, thus greatly reducing cross-contamination between the samples and the operator.
For this reason, the device can handle samples with high pathogenicity.
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- Please enter your reservation through the reservation system before using.
- Please limit the use (reservation) time to up to 3 hours.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee 100 yen/hour
Equipment Photo
Preparation

CO2 Incubator

Model
(Manufacturer)
MOC-170AICUV-PJ (PHCbi)
Features and Specifications, etc. [Overview]
 This device can be used for the cultivation of animal cells.
 
[Specifications]
 - Operating conditions: 37°C (±0.1°C), 5%CO2 (±0.15%CO2)
 - Content: 165L
 - Humidity inside the instrument: 95% (±5%)
 - Number of trays (shelves): 4
 - UV lamp: 1 piece
 - Heating method: DHA method (heater jacket + air jacket)
 - Temperature control: PID control method
 - CO2 concentration control: PID control method (dual IR sensors)
 - Internal circulation system: Breeze mixing
 - Temperature and concentration display: LCD (color touch panel)
 - Alarm function: temperature, gas concentration, door open/close
 - USB ports
 
[Features]
 - Stable CO2 concentration control.
- Large tray area allows for the installation of many culture vessels.
- Automatic control reduces condensation inside the vessel.
- Easy management of acquired data parameters (internal temperature, CO2 concentration, door open/close, alarms) .
- Decontamination of the vessel with hydrogen peroxide is possible (total decontamination process: approx. 135 min.) .
 
[Usage Examples]
 - Maintenance of cultured cells.
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- Please enter your reservation through the reservation system before using.
- Please limit the use (reservation) time to up to 3 hours.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo
Preparation

Optical Microscopes

Model
(Manufacturer)
IX70 (OLMPUS)
Features and Specifications, etc. [Overview]
 This device allows for the observation of animal cells being cultured (maintained) in the same room.
 
[Specifications]
 - Objective Lens: x4, x10, x20
 - Eyepiece: x10
 
[Features]
 - The camera and computer (Windows 2000 Professional) provided with the camera can be used to take pictures and acquire data.
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo
Preparation

Gene Delivery Systems

Model
(Manufacturer)
AMAXANucleofector (Lonza)
Features and Specifications, etc. [Overview]
 This device allows electroporation (that is, introducing target genes into cells) by applying electrical pulses to the cells.
[Specifications]
 - Graphic display
 - IC card slots

[Features]
 - Standard equipment for gene transfer devices.
- Easy to operate.
- Highly efficient introduction of genes (plasmid DNA, shRNA, miRNA, RNA, etc.) in a single cuvette format (100 μL) .
- Gene transfer to primary cultured cells and neurons is possible.
- High cell viability and cell function can be maintained.
- Optimized kits (sold separately) are available for 160 or more cell types.
Location Biosafety Level 2 Room (Room 305, University Building 1)
Remarks - This equipment is available for loan.
- If you wish to use the cellular analysis, please contact the Cell Function Analysis Laboratory.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo
Preparation

Gene Delivery Systems

Model
(Manufacturer)
GenePulserII (BIO-RAD)
Features and Specifications, etc. [Overview]
 This device allows electroporation (that is, introducing target genes into cells) by applying electrical pulses to the cells.

[Specifications]
 Gene Pulsar II
 - Output waveform: Exponential decay pulse
 - Output power: 50 to 2,500V
 - Voltage adjustment range: 10V increments (High range), 2V increments (Low range)
 - Volume: 20 to 80 μL, 40 to 400 μL, 200 to 800 μL
 Pulse Controller (PC) II
 - For bacteria and yeast
 - Set resistance value: 50, 100 to 1,000Ω (in 100Ω increments)
 Capacitance Extender (CE) II
 - For animal and plant cells
 - Capacitor setting value: 25 to 3,275 μF (25 μF increments)

[Features]
 - Usable with microorganisms (E. coli, bacteria), yeast, and animal and plant cells.
- Parameters (time constant, voltage, pulse interval, pulse duration) can be changed according to the selected waveform.
- Protocols for highly versatile cell types have already been established.
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - This equipment is available for loan.
- If you wish to use the cellular analysis, please contact the Cell Function Analysis Laboratory.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo
Preparation

Cooling Centrifuge

Model
(Manufacturer)
himacCF7D2 (HITACH)
Features and Specifications, etc. [Overview]
 The instrument can centrifuge cell samples under cooling.

[Specifications]
 - Swing rotor compatible type
 - Rotor and capacity: RT5S4, 15mL (4 tubes/bucket, x4), 50mL (1 tube/bucket, x4)
 - Maximum speed: 7,000 rpm (30 to 7,000 rpm)
 - Maximum centrifugal acceleration: 6,570 xg (with RT8A rotor)
 - Temperature setting range: -9 to 40°C
 - Time setting range: 1 to 99 minutes, continuous (free)
 - Mode: Manual mode, memory mode (4 patterns)

[Features]
 - Easy to operate.

[Usage Examples]
 - Cell preparation.
- Concentration of samples.
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo
Preparation

Cooling Centrifuge

Model
(Manufacturer)
MX301 (TOMY)
Features and Specifications, etc. [Overview]
 This device can centrifuge trace samples at high speed under cooling.

[Specifications]
 - Angle rotor compatible type
 - Rotor racks and capacities: AR015-24 (2mL x 24 bottles), AR005-24 (0.5mL x 24 bottles), AR500-04 (15mL x 4 bottles, 50mL x 4 bottles)
 - Maximum speed: 16,000 rpm (3 to 160 rpm/1 to 232 xg)
 - Maximum RCF: 21,130 xg
 - Temperature setting range: -9 to 35°C
 - Time setting range: 1 to 99 minutes, continuous (free)
 - Mode: Manual mode, memory mode (3 patterns), flash mode, soft brake

[Features]
 - Easy to operate.

[Usage Examples]
 - Cell preparation.
- Concentration of samples.
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo
Preparation

Large High-speed Cooling Centrifuge

Model
(Manufacturer)
AvantHP-26XPI (Beckman Coulter)
Features and Specifications, etc. [Overview]
 This machine is capable of high-speed mass centrifugation under cooling.

[Specifications]
 - Angle rotor / Swing rotor compatible type
 - Rotor capacity: JLA8.100 (6 x 1,000mL, max. 8,000rpm/15,970 xg), JLA10.500 (6 x 500mL, max. 10,000rpm/18,100 xg), JA-12 (12 x 50mL, max. 12,000rpm/23,200 xg)
 - Centrifuge tubes and bottles: 12PA tube, 40PA tube, 30PC bottle, 50 mL bottle, 500 mL bottle, 1,000 mL bottle
 - Maximum speed: 26,000 rpm (100 rpm/xg increments)
 - Maximum centrifugal force: 15,970 xg (with JLA8.1)
 - Temperature setting range: -10 to 40°C (in 0.1°C increments)
 - Time setting range: 1min.~99hour 59min., continuous (free)
 - Control panel

[Features]
 - Autoclave sterilizable for rotors.
- A maximum of 6L of sample can be processed (when JLA8.1 is used).

[Usage Examples]
 - Virus enrichment, bacteria separation, cell separation, diffusion separation, organelle (mitochondria, chloroplast) separation, cell membrane separation.
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo
Preparation

Autoclave for Sterile Surgical Instruments

Model
(Manufacturer)
LPS-500 (TOMY)
Features and Specifications, etc. [Overview]
 This device can sterilize items (such as media and equipment) using high-pressure steam.

[Specifications]
 - Temperature setting range: 105 to 135°C
 - Maximum operating pressure: 0.281MPa
 - Internal can capacity: 58L
 - Safety devices: heating prevention inside the body, heating prevention on the outside of the body, pressure prevention outside the body, detection of temperature sensor breaks, air burning prevention, and lid heat cut-off carburetor.

[Features]
 - Easy to operate.
 - Due to its large capacity, it can process a large volume of items for sterilization at once.

[Usage Examples]
 - Sterilization of heat-resistant instruments.
 - Sterilization of culture media and buffer solutions.
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- Sterilization equipment for reagents and instruments used in aseptic manipulation.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee 100 yen/time
Equipment Photo
Preparation

Autoclave for Contaminated Waste

Model
(Manufacturer)
MLS-2420 (SANYO)
Features and Specifications, etc. [Overview]
 This device can sterilize items (such as media and equipment) using high-pressure steam.

[Specifications]
 - Temperature setting range: 105 to 121°C
 - Pressure setting range: 0 to 300 kPa
 - Time setting range: 1 to 180 minutes
 - Internal can capacity: 20L
 - Waste tank capacity: 3L

[Features]
 - Easy to operate.

[Usage Examples]
 - Sterilization of pathogenic samples and the tools used to handle them, generated in Room 305 (BSL2) .
Location Biosafety Level 2 room (Room 305, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- This equipment is dedicated to the sterilization of contaminants generated in the Room 305 (BSL2) .
No contaminants from outside the room can be brought in.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo
Preparation