Flow Cytometer



Flow Cytometer Analyzer

Model
(Manufacturer)
FACSCalibur (BD Bioscience)
Features and Specifications, etc. [Overview]
 This device enables selective analysis of target cells labeled with fluorescent dyes.
[Specifications]
 - 2 laser: 488nm (3), 635nm (1) *Number of detectors in parentheses
 - 4-color (4 detectors)
 - 8 parameters
 - Maximum processing speed: 10,000 events/sec.
 - Computer (OS): PowerMac G5 (MacOSX)
 - Software: CellQuest Pro
 - Data management: FCS files
[Features]
 - Turn the power ON and you can start measuring in about 10 minutes.
- Compared to other models, it is easier to operate.
- It is ideal as an introductory device for flow cytometry.
[Usage Examples]
 - Phenotypic analysis of cells stained with fluorescently labeled antibodies or cells artificially expressing fluorescent proteins.
- Intracellular signaling analysis using fluorescently labeled phosphorylated antibodies.
Location Central Research Center (Room 317, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- Please enter your reservation through the reservation system before using.
- Please limit the use (reservation) time to up to 3 hours.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee 100 yen/10minute
Equipment Photo

Flow Cytometer Analyzer

Model
(Manufacturer)
FACSCalibur (BD Bioscience)
Features and Specifications, etc. [Overview]
 This device enables selective analysis of target cells labeled with fluorescent dyes.
[Specifications]
 - 1 laser: 488nm (3) *The number in parentheses indicates the number of detectors.
 - 3-color (3 detectors)
 - 7 parameters
 - Maximum processing speed: 10,000 events/sec.
 - Computer (OS): PowerMac G5 (MacOSX)
 - Software: CellQuest Pro
 - Data management: FCS files
[Features]
 - Turn the power ON and you can start measuring in about 10 minutes.
- Compared to other models, it is easier to operate.
- It is ideal as an introductory device for flow cytometry.
[Usage Examples]
 - Phenotypic analysis of cells stained with fluorescently labeled antibodies or cells artificially expressing fluorescent proteins.
- Intracellular signaling analysis using fluorescently labeled phosphorylated antibodies.
Location Bantane Laboratory (4F, West Wing)
Remarks - New users are requested to contact Yasuto Kondo in Pediatrics.
Equipment Manager
Extension Number
Yasuto Kondo (Pediatrics, Bantane Hospital)
5739
Usage Fee 100 yen/10minute
Equipment Photo

Flow Cytometer Analyzer

Model
(Manufacturer)
CytoFLEX S (Beckman Coulter)
Features and Specifications, etc. [Overview]
 This device enables selective analysis of target cells labeled with fluorescent dyes.
[Specifications]
 - 4 lasers: 488nm (2), 638nm (3), 405nm (4), 561nm (4) *The number in parentheses indicates the number of detectors.
 - 13-color (13 detectors)
 - 15 parameters
 - Computer (OS): Windows 10 Professional ver. 20H2
 - Software: CytExpert
 - Data management: FCS files
[Features]
 - Capable of simultaneous fluorescence analysis of up to 13 colors.
- Automatic compensation function.
- Detectors using Avalanche photodiodes provide excellent red sensitivity.
- High resolution (<300nm particles (488nm-SSC), <80nm particles (405nm-SSC).
[Usage Examples]
 - Phenotypic analysis of cells stained with fluorescently labeled antibodies or cells artificially expressing fluorescent proteins.
- Intracellular signaling analysis using fluorescently labeled phosphorylated antibodies.
Location Central Research Center (Room 317, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- Please enter your reservation through the reservation system before using.
- Please limit the use (reservation) time to up to 3 hours.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee 100 yen/10minute
Equipment Photo

Flow Cytometer Analyzer

Model
(Manufacturer)
Gallios (Beckman Coulter)
Features and Specifications, etc. [Overview]
 This device enables selective analysis of target cells labeled with fluorescent dyes.
[Specifications]
 - 3 lasers: 488nm (5), 640nm (3), 405nm (2) *The number in parentheses indicates the number of detectors.
 - 10-color (10 detectors)
 - 62 parameters
 - Maximum analysis speed: 25,000 events/sec
 - Computer (OS): Windows Vista Business
 - Software: Gallios Software
 - Data management: LMD files
[Features]
 - Capable of simultaneous fluorescence analysis of up to 10 colors.
- Capable of performing cell analysis at high speed.
- Automated measurement through integration of the autosampler and software.
[Usage Examples]
 - Phenotypic analysis of cells stained with fluorescently labeled antibodies or cells artificially expressing fluorescent proteins.
- Intracellular signaling analysis using fluorescently labeled phosphorylated antibodies.
Location Central Research Center (Room 317, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- Please enter your reservation through the reservation system before using.
- Please limit the use (reservation) time to up to 3 hours.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee 100 yen/10minute
Equipment Photo

Flow Cytometer Cell Sorter

Model
(Manufacturer)
MoFlo Astrios   High-speed Cell Sorter (Beckman Coulter)
Features and Specifications, etc. [Overview]
 This device can selectively and with high purity sort (sort) target cells labeled with fluorescent dyes from heterogeneous cell populations.
[Specifications]
 - 2 laser: 488nm (5), 640nm (3) *Number of detectors in parentheses
 - 8-color (8 detectors)
 - Maximum analysis speed: 100,000 events/sec
 - Maximum sorting speed: 70,000 events/sec (Jet-in-Air method)
 - Measurement particle size range: 0.2 to 30 μm
 - Sorting: 2-way sorting (15mL, 50mL), 6-way sorting (5mL), plate sorting (96-well)
 - Touch panel
 - Computer (OS) : Windows 7 Professional
 - Software: Summit Software ver. 6.3.1
 - Data management: FCS files
[Features]
 - Capable of simultaneous fluorescence analysis of up to 8 colors.
- Due to the Jet-in-Air method, high-speed sorting is possible.
[Usage Examples]
 - Capable of sorting cells stained with fluorescently labeled antibodies or cells artificially expressing fluorescent proteins.
- Target cells can be sorted as single cells, suitable for gene expression analysis.
Location Central Research Center (Room 317, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- The administrator will handle the machine setup and reservation entries prior to use, so those wishing to use it are requested to contact the Cell Function Analysis Laboratory in advance.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee 1,000 yen/hour
Equipment Photo

Flow Cytometer Cell Sorter

Model
(Manufacturer)
BD FACSAria III Cell Soter (BD Biosceince )
Features and Specifications, etc. [Overview]
 This device can selectively sort (sort) target cells labeled with fluorescent dyes from heterogeneous cell populations.
[Specifications]
 - 4 lasers: 488nm (2), 633nm (3), 405nm (2), 561nm (5) *The number in parentheses indicates the number of detectors.
 - 12-color (12 detectors)
 - Maximum sorting speed: 30,000 events/sec (cuvette flow cell method)
 - Measurement particle size range: 0.5 to 30 μm
 - Sorting: 2-way sorting (15mL), 4-way sorting (2mL, 5mL), plate sorting (96-well)
 - Computer (OS): Windows 10
 - Software: BD FACS Diva softwar ever. 9.0
 - Data management: FCS files
[Features]
 - Capable of simultaneous fluorescence analysis of up to 12 colors.
- Easier to operate than the MoFlo Astrios.
[Usage Examples]
 - Capable of sorting cells stained with fluorescently labeled antibodies or cells artificially expressing fluorescent proteins.
- Target cells can be sorted as single cells, suitable for gene expression analysis.
Location Central Research Center (Room 317, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- Those wishing to use it are requested to contact the Cell Function Analysis Laboratory in advance (before reservation entries).
- Accudrop Beads must be purchased by users.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee 1,000yen/hour
Equipment Photo

Flow Cytometry Analysis Software

Model
(Manufacturer)
Kaluza (Beckman Coulter)
Features and Specifications, etc. [Overview]
 This equipment can thoroughly analyze and graph data obtained through flow cytometry.
[Specifications]
 - Software: Kaluza Soft ver. 2.1
[Features]
 - Compatible with data obtained from almost all flow cytometers.
- Various analyses are possible through drag-and-drop functionality.
- Capable of processing list mode files conforming to the FCS standard up to version 3.1.
- Multi-color data can be analyzed easily and efficiently through four simple control panels.
- Capable of real-time processing of multi-color files with up to 20 million events.
- An innovative interface designed with a priority on workflow and user-friendliness.
Location Central Research Center (Room 317, University Building 1)
Remarks - New users are requested to contact the Cell Function Analysis Laboratory.
- Please enter your reservation through the reservation system before using.
- Please limit the use (reservation) time to up to 3 hours.
Equipment Manager
Extension Number
Tezuka (Cell Function Analysis Laboratory)
2570
Usage Fee -
Equipment Photo