Skip global navigation and go to header navigation

Skip global navigation and read the article

Skip global navigation and go to local navigation

Skip global navigation and go to footer navigation




Centrifuge



Concentration Centrifuge

Model
(Manufacturer)
DNA120 SpeedVac (Thermo Fisher)
Features and Specifications, etc. Using centrifugal force to prevent bumping and foaming of samples, the device lowers the boiling point of the solvent under reduced pressure and promotes solvent evaporation through heating.
It allows for the rapid and safe concentration and drying of various samples.
 
【Specifications】
Compatible solvents Water, ethanol
Maximum throughput 36 1.5/2.0 mL tubes
Maximum vacuum 10 Torr (1.3 kPa) or less
Location Omics Analysis Laboratory (Room 304, University Building 1)
Remarks -
Equipment Manager
Extension Number
Maeda (Omics Analysis Laboratory)
9814
Usage Fee -
Equipment Photo

Microplate Centrifuge

Model
(Manufacturer)
HITACHI 05PR-22 (HITACHI)
Features and Specifications, etc. Microplate centrifuge for PCR use

【Specifications】
Maximum rotational speed 5000 rpm
Location Central Research Center (Room 317, University Building 1)
Remarks -
Equipment Manager
Extension Number
Maeda (Omics Analysis Laboratory)
9814
Usage Fee -
Equipment Photo

Tabletop Microplate Centrifuge

Model
(Manufacturer)
himac CT6E (himac)
Features and Specifications, etc. Microplate centrifuge for PCR use

【Specifications】
Maximum rotational speed 6000 rpm
Maximum telecentric acceleration 4770 g
Speed control range 300-6000 rpm
Acceleration and deceleration settings: 2 levels each + brake free during deceleration
Location Central Research Center (University Building 1, Room 317)
Remarks -
Equipment Manager
Extension Number
Maeda (Omics Analysis Laboratory)
9814
Usage Fee -
Equipment Photo

Micro High Speed Cooling Centrifuge

Model
(Manufacturer)
MX-307 (TOMY)
Features and Specifications, etc. - Compatible with rack-in-rotor with ultra-light weight and one-touch attachment/detachment.
- Center jog dial with excellent operability.
- A two-color LED display switches colors between centrifugal and stop.

【Specifications】
Maximum rotation speed: 16000rpm Maximum centrifugal acceleration: 21130G
Tachometer: 300 to 16,000 rpm Temperature setting range: -9 to +45°C                              
Power supply: AC100V 50/60Hz 12A Rotor: AR510-04; 4 x 50ml, 4 x 15ml, AR015-24: 24 x 1.5ml
Location Bioimaging Analysis Laboratory (Control Room, Room 113, University Building 1)
Remarks - When using the equipment, please be sure to fill out the logbook provided with it.
Equipment Manager
Extension Number
Tominaga (Bioimaging Analysis Laboratory)
2320
Usage Fee -
Equipment Photo

Micro High Speed Cooling Centrifuge

Model
(Manufacturer)
CF15RX II
Features and Specifications, etc. Cooling centrifuge for 1.5-2.0 mL tubes

【Specifications】
Maximum rotational speed 15,000 rpm
Maximum telecentric acceleration 22,260 g
Temperature display -9 to 40°C
Acceleration and deceleration settings: 4 levels each + brake free during deceleration
Location Joint Usage Research Facility Low Greenhouse (Room 411, University Building 1)
Remarks -
Equipment Manager
Extension Number
Maeda (Omics Analysis Laboratory)
9814
Usage Fee -
Equipment Photo

High Speed Cooling Centrifuge

Model
(Manufacturer)
Suprema21 (TOMY)
Features and Specifications, etc. Cooling centrifuge capable of high-speed rotation
Exceeding the maximum centrifugal acceleration or allowable rotation speed of the tube used is prohibited.

【Specifications】
- Max. rpm: Depends on the tube used
- Maximum RPM: Depends on the tube used.
- Drive motor: Induction motor
- Setting method: Jog dial method
- Temperature setting: every 1°C Setting range: -9 to +35℃
- Display method: Digital
- Automatic rotor identification

【Rotors】
- NA-11: 6 x 250 mL tubes
- NA-23: 12 x 50 mL conical tubes  
or 12 x 15 mL conical tubes (with adapter)

【Adapters】
- Adapter for NA-23 (CA1500-01): for 15 ml conical tube

Installed in October 2023
Location Protein and Gene Analysis Laboratory (Room 415, University Building 1)
Remarks - Always check the maximum centrifugal acceleration or allowable rotation speed of the tubes before use.
- Please ensure to book this equipment through the reservation system when using it.
- When using the equipment, please be sure to fill out the logbook provided with it.
Equipment Manager
Extension Number
Tsukamoto (Laboratory for Proteins and Genes)
9928
Usage Fee -
Equipment Photo

Compact Cooling Centrifuge

Model
(Manufacturer)
CF7D2 (HITACHI)
Features and Specifications, etc. Cooling centrifuge for 15 mL. 50 mL tubes

【Specifications】
Maximum rotational speed 7000 rpm
Maximum telecentric acceleration 6570 g
Speed control range 300-7000 rpm
Temperature display -9 to 40°C
Acceleration and decompression settings: slow, fast, 6-step switching each
Location Joint Usage Research Facility Low Greenhouse (Room 411, University Building 1)
Remarks -
Equipment Manager
Extension Number
Maeda (Omics Analysis Laboratory)
9814
Usage Fee -
Equipment Photo

Compact Cooling Centrifuge

Model
(Manufacturer)
CF7D2 (HITACHI)
Features and Specifications, etc. Cooling centrifuge for 15 mL. 50 mL tubes

【Specifications】
Maximum rotational speed 7000 rpm
Maximum telecentric acceleration 6570 g
Speed control range 300-7000 rpm
Temperature display -9 to 40°C
Acceleration and decompression settings: slow, fast, 6-step switching each
Location Joint Usage Research Facility Low Greenhouse (Room 411, University Building 1)
Remarks -
Equipment Manager
Extension Number
Maeda (Omics Analysis Laboratory)
9814
Usage Fee -
Equipment Photo

Multi-Shelf Cooling Centrifuge

Model
(Manufacturer)
AX521 (TOMY)
Features and Specifications, etc. Cooling centrifuge for 15 mL. 50 mL tubes

【Specifications】
Maximum rotational speed 10,000 rpm
Maximum telecentric acceleration 11,740 g
Temperature display -9 to 35°C
Acceleration and deceleration settings: 3 levels each + brake free during deceleration
Location Joint Usage Research Facility Low Greenhouse (Room 411, University Building 1)
Remarks -
Equipment Manager
Extension Number
Maeda (Omics Analysis Laboratory)
9814
Usage Fee -
Equipment Photo